Advertisement

Ilsco Lugs Chart

Ilsco Lugs Chart - Hand dieless color number no. Tightening torque values for ilsco sockethead screw connectors. Web mps for ilsco hydraulic tools. Insert the conductor(s) and tighten all set screws per the manufacturer’s recommendations. When using other listed tools, consult chart for crimps die index. Apply oxide inhibitor compound and wire brush into the stranding. Identifies the proper compression die. Internal socket size across flats inches. 87 002 1863 (la 6a) 6 14. Web with ilsco’s optimum crimp design, surecrimp connectors provide a tight crimp profile for strong connections, an increased contact area to reduce resistance, and the elimination of flash potential.

ILSCO TA500 4500MCM ALCU LUG Gordon Electric Supply, Inc.
Ilsco Lug Torque Chart
Tool Chart for Panduit OneHole and TwoHole Code Tool...Tool Chart for
ILSCO AU2/0 UL/CSA Listed 2/014 AWG Aluminum Dual Rated Mechanical
lugs GlobeElectricSupply
Electrical Lug Torque Specs Chart Eaton chartdevelopment
Ilsco Lug Torque Chart
Ilsco SGB4 Ground Lug OneMonroe Titan
Electrical Equipment & Supplies ILSCO CLND40012134 400 kcmil 300/313
Ilsco Lug Torque Chart

Web With Ilsco’s Optimum Crimp Design, Surecrimp Connectors Provide A Tight Crimp Profile For Strong Connections, An Increased Contact Area To Reduce Resistance, And The Elimination Of Flash Potential.

6 14 s6 (3/8x3/8) (3/8 narrow) la50 1. Web mps for ilsco hydraulic tools. (1/2 wide) s6w (3/8x1/2) da 6. Apply oxide inhibitor compound and wire brush into the stranding.

Alongside The Surecrimp Connectors, Ilsco Also Offers The Surecrimp Dies, Made Of Corrosion Resistant Stainless Steel, That Produces Durable Circumferential Crimps.

When using other listed tools, consult chart for crimps die index. Tightening torque in inch pounds. Hand dieless color number no. Offers maximum conductivity and excellent crimping characteristics.

Web Rated To 90 ̊ C.

Insert the conductor(s) and tighten all set screws per the manufacturer’s recommendations. Tightening torque in inch pounds. Web brush the stripped portion of the conductor to remove oxide film with a stainless steel wire brush. Although lightning is a commonly known threat to electrical equipment, over 80% of all surges are actually caused by internal and power.

Do Not Retighten After Properly Torqued.

Surgency™ for commercial, industrial, and residential applications protects equipment by capturing surges before they cause damage. Identifies the proper compression die. Web ilsco mechanical screw connectors. Internal socket size across flats inches.

Related Post: